AHSC-1000

•  Ultimate Authentication Performance
•  Scalable
•  Advanced Global Functionality based on peer-to-peer communication
•  High Level Cyber Security
SPECIFICATIONS
General Information  
Primary Power PoE 802.3at / 9 - 24 VDC ± 20%, 550 mA maximum (reader current not included)
Primary Host Communication Ethernet: 100Base-TX
256bit AES* symmetric encryption for Controller to Server and Inter-Controller communications
Secondary Host Communication
Bluetooth 5.2
Third Host Communication Wi-Fi IEEE 802.11ac 5GHz, or 2.4GHz/5GHz IEEE 802.11n
256bit AES* symmetric encryption for Controller to Server and Inter-Controller communications
Ethernet network connection Port 1: Ethernet: 100Base-TX
Port 2: Ethernet: 100Base-TX
(Configurable for Port Failover)
RS-485 connection Port 1: Armatura RS-485 / OSDP V2.2
Port 2: Armatura RS-485 / OSDP V2.2
Port 3: Armatura RS-485 / OSDP V2.2
(Configurable for Port Redundancy dedicated on port 2 & 3)
Number of Ports 2*TCP/IP (IPv4 & IPv6)
3*RS-485
2*Wiegand
1*RS-232
Inputs 4 states supervision, resistor values (5% tolerance),
Normally open contact: use 1.2k, 2.2k. 4.7k or 10k
Normally closed contact: use 1.2k, 2.2k. 4.7k or 10k
Dedicated Panel Tamper IO Input*
Dedicated Microchip Control Fire Alarm IO Input & REX Input for catastrophic situation
Outputs 1 relay, 1* Form-C with dry contacts
Normally Open Contact Rating 5A @ 30Vdc resistive
Normally Closed Contact Rating 5A @ 30Vdc resistive
On-Board Monitor Size: 2.4", Resolution: 320*240, TFT Monitor
Quickly view status of board, connected doors and for configuration information display
On-Board Webserver Webserver for System Configuration and Management
Dashboard for Controller Status Monitoring,
Device Connection Status Monitoring & Configuration, Performance Status,
Server Primary Controller Setting,
Network Status Monitoring & Setting,
IP Access Filter, SSL / TLS Certificates Setting,
Access Log Export, Controller Reset, Debug Status Monitoring,
Operation Log Monitoring, User Management,
Date & Time Setting, Daylight Saving Time Setting,
NTP Server Setting, General Status, Controller Information
RFID Card Capacity As a Main-Controller: 800,000 (Storage)
As a Door Unit: 400,000 (1:N) / 800,000 (1:1)
Maximum RFID Card Number Length Maximum RFID Card Number Length
Mobile Credential Capacity 400,000 (1:N) (Bluetooth)
400,000 (1:N) (NFC)
400,000 (1:N) (Dynamic QR Code)
Fingerprint Capacity As a Primary Controller: 100,000 (Storage) As a Door Unit: 50,000 (1:N) / 100,000 (1:1)
Face Capacity As a Primary Controller: 100,000 (Storage)
As a Door Unit: 5,000 (1:N) / 100,000 (1:1)
Palm Capacity As a Primary Controller: 5,000 (Storage)
As a Door Unit: 3,000 (1:N) / 5,000 (1:1)
Transaction Buffer 5,000,000 Events
Access Level 100,000 Levels
On-Board Access Point Control 1 access point on board
On-Board Reader Support 2 (OSDP over RS-485) or 2 (Wiegand) with on-board IO
Maximum Access Point 129 (with 32pcs AHDU-1460 modules through TCP/IP connection)
97 (with 24pcs AHDU-1460 modules through Armatura RS-485 over RS-485 connection)
Maximum Readers 258 (with 32pcs AHDU-1460 modules through TCP/IP connection)
194 (with 24pcs AHDU-1460 modules through Armatura RS-485 over RS-485 connection)
Maximum Inputs 12,801 (with 33pcs AHDU-1460 modules through TCP/IP connection
+ 792pcs AHEB-1602 IO Expansion Board through OSDP over RS-485 connection)
Maximum Outputs 12,801 (with 33pcs AHDU-1460 modules through TCP/IP connection
+ 792pcs AHHEB-0216 IO Expansion Board through OSDP over RS-485 connection)
Maximum IO Board 24pcs (2*High Speed RS-485 communication)
Maximum DU Modules 32pcs (1*TCP/IP communication with AES-256 & TLS1.2 end to end secure channel)
24pcs (OSDP over RS-485 communication with AES-128 end to end secure channel)
DOOR UNIT CONTROLLER INTERFACE  
Input Voltage 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader
Maximum Input Current 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader
TCP/IP Mode Ethernet: 100Base-TX
TCP/IP Protocol 802.1X, VLAN, SSH, IPv4, IPv6, WebSocket
TCP/IP Encryption Complied up to TLS1.2, AES-256 end to end secured communication channel
TCP/IP Communication Spada Protocol over WebSocket
RS-485 Protocol AES-256, Armatura RS-485 Secure Channel
Armatura RS-485 Mode 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
Data Inputs TCP/IP standard supported.
Maximum TCP/IP cable length: 330ft. (100m)
RS-485 standard supported.
Maximum RS-485 cable length: 3937ft. (1200m
RFID / BIOMETRICS READER INTERFACE  
Input Voltage 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader
Maximum Input Current 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader
RS-485 Protocol AES-128, OSDP Secure Channel
OSDP Mode 9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
3rd Party reader: support OSDP V2.2 or above
Wiegand Read: support up to 128 bits / Write: Support 26 / 34 / 37 bit, and other customised card formats
Tamper Input (Wiegand) TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum
Buzzer Output (Wiegand) TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum
LED Output (Wiegand) TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum
Data Inputs RS-485, OSDP and Wiegand standards supported.
Maximum RS-485 /OSDP cable length: 3937ft. (1200m)
Maximum Wiegand cable length: 328ft (100m)
IO EXPANSION BOARD INTERFACE  
RS-485 Protocol TLS 1.2, AES-128, OSDP V2.2 Secure Channel
OSDP Mode 9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
Maximum cable length: 2,000 ft. (609.6m)
Data Inputs OSDP and Wiegand standards supported. Maximum cable length: 500 ft. (152m)
SOFTWARE INTERFACE  
TCP/IP Mode Ethernet: 100Base-TX
TCP/IP Protocol NTP, SNMP V2 /V3, 802.1X, vLan, SSH, MQTT, IPv4, IPv6, DNS, DDNS
TCP/IP Encryption Complied up to TLS1.2, AES-256 end to end secured communication channel
TCP/IP Communication Spada Protocol over MQTT
CABLE REQUIREMENT  
Power & Relays One twisted pair, 18-16 AWG
Ethernet CAT-5, minimum 330 ft. (100m)
Ethernet Failover Port CAT-5, minimum 330 ft. (100m)
RS-485 Reader Port 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
One twisted pair with drain wire and shield, 120 ohm resistance, 22-18 AWG,
Maximum cable length: 3937ft (1200m)
RS-485 I/O Device Port 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
One twisted pair with drain wire and shield, 120 ohm resistance, 22-18 AWG,
Maximum cable length: 3937ft (1200m)
RS-485 Failover Port 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
One twisted pair with drain wire and shield, 120 ohm resistance, 22-18 AWG,
Maximum cable length: 3937ft (1200m)
Wiegand Port 20 AWG shielded Wiegand wire ,328ft. (100m)
MECHANICAL  
Dimensions 4.8” W x 10.2” L x 2.5” H in. (122 x 260 x 62.5mm)
Weight approx. 30oz (830g)
Mounting Supported DIN35 Rail
Compatible with UTA89 Din Rail Adapter for screwing on switchgear (Sold Separately)
Wall mount
Housing Material ABS-PC UL-94 V2
ENVIRONMENTAL  
Temperature -22°F ~ 158°F (-30°C~70°C), Operating & Storage
Humidity 0-95%RHNC
Certification(s)* CE, FCC, RoHS, UL294
Security Rating Secure Data Storage in EAL 6+ Certified Crypto Chip
SOFTWARE  
Supported Software Armatura--One Security System
Download
AHSC-1000_Leaflet_11-22-2022
357.99KB     2022-12-16
Download
ARMATURA_Armatura ID UM_EN v1.3_20221031
6.19MB     2022-12-16
Download
ARMATURA_Armatura CONNECT UM_EN v1.3_20221031
5.78MB     2022-12-16
Download
ARMATURA_Armatura Horizon Controller UM_EN v1.5_20221214
13.21MB     2022-12-15
Download